Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Lancet Planet Health ; 7(11): e900-e911, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37940210

RESUMEN

BACKGROUND: High-level exposure to indoor air pollutants (IAPs) and their corresponding adverse health effects have become a public concern in China in the past 10 years. However, neither national nor provincial level burden of disease attributable to multiple IAPs has been reported for China. This is the first study to estimate and rank the annual burden of disease and the financial costs attributable to targeted residential IAPs at the national and provincial level in China from 2000 to 2017. METHODS: We first did a systematic review and meta-analysis of 117 articles from 37 231 articles identified in major databases, and obtained exposure-response relationships for the candidate IAPs. The exposure levels to these IAPs were then collected by another systematic review of 1864 articles selected from 52 351 articles. After the systematic review, ten IAPs with significant and robust exposure-response relationships and sufficient exposure data were finally targeted: PM2·5, nitrogen dioxide, sulphur dioxide, ozone, carbon monoxide, radon, formaldehyde, benzene, toluene, and p-dichlorobenzene. The annual exposure levels in residences were then evaluated in all 31 provinces in mainland China continuously from 2000 to 2017, using the spatiotemporal Gaussian process regression model to analyse indoor originating IAPs, and the infiltration factor method to analyse outdoor originating IAPs. The disability-adjusted life-years (DALYs) attributable to the targeted IAPs were estimated at both national and provincial levels in China, using the population attributable fraction method. Financial costs were estimated by an adapted human capital approach. FINDINGS: From 2000 to 2017, annual DALYs attributable to the ten IAPs in mainland China decreased from 4620 (95% CI 4070-5040) to 3700 (3210-4090) per 100 000. Nevertheless, in 2017, IAPs still ranked third among all risk factors, and their DALYs and financial costs accounted for 14·1% (95% CI 12·3-15·6) of total DALYs and 3·45% (3·01-3·82) of the gross domestic product. Specifically, the rank of ten targeted IAPs in order of their contribution to DALYs in 2017 was PM2·5, carbon monoxide, radon, benzene, nitrogen dioxide, ozone, sulphur dioxide, formaldehyde, toluene, and p-dichlorobenzene. The DALYs attributable to IAPs were 9·50% higher than those attributable to outdoor air pollution in 2017. For the leading IAP, PM2·5, the DALYs attributable to indoor origins are 18·3% higher than those of outdoor origins. INTERPRETATION: DALYs attributed to IAPs in China have decreased by 20·0% over the past two decades. Even so, they are still much higher than those in the USA and European countries. This study can provide a basis for determining which IAPs to target in various indoor air quality standards and for estimating the health and economic benefits of various indoor air quality control approaches, which will help to reduce the adverse health effects of IAPs in China. FUNDING: The National Key Research and Development Program of China and the National Natural Science Foundation of China.


Asunto(s)
Contaminantes Atmosféricos , Ozono , Radón , Humanos , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Monóxido de Carbono/análisis , Dióxido de Azufre/análisis , Benceno/efectos adversos , Benceno/análisis , Dióxido de Nitrógeno/efectos adversos , Dióxido de Nitrógeno/análisis , Formaldehído/análisis , Costo de Enfermedad , Material Particulado/análisis , Radón/análisis , Ozono/análisis , Tolueno/análisis
2.
Indoor Air ; 32(11): e13154, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437653

RESUMEN

Indoor radon exposure is thought to be associated with adverse health effect as lung cancer. Lung cancer incidences in China have been the highest worldwide during the past two decades. It is important to quantitively address indoor radon exposure and its health effect, especially in countries like China. In this paper, we have conducted a meta-analysis based on indoor radon and its health effect studies from a systematic review between 2000 and 2020. A total of 8 studies were included for lung cancer. We found that the relative risk (RR) was 1.01 (95% CI: 1.01-1.02) per 10 Bq/m3 increase of indoor radon for lung cancer in China. The subgroup analysis found no significant difference between the conclusions from the studies from China and other regions. The health effect of indoor radon exposure is relatively consistent for the low-exposure and high-exposure groups in the subgroup analysis. With a better understanding of exposure level of indoor radon, the outcomes and conclusions of this study will provide supports for next phase of researches on estimation of environmental burden of disease by indoor radon exposures in countries like China.


Asunto(s)
Contaminación del Aire Interior , Neoplasias Pulmonares , Radón , Humanos , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Factores de Riesgo , Radón/efectos adversos , Radón/análisis , Neoplasias Pulmonares/epidemiología , Neoplasias Pulmonares/etiología , China/epidemiología
3.
Indoor Air ; 32(11): e13178, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437656

RESUMEN

Ozone and byproducts of ozone-initiated reactions are among the primary pollutants in aircraft cabins. However, investigations of the spatial distribution and reaction mechanisms of these pollutants are insufficient. This study established a computational fluid dynamics-based model to evaluate ozone and byproduct distribution, considering ozone reactions in air, adsorption onto surfaces, and byproduct desorption from surfaces. The model was implemented in an authentic single-aisle aircraft cabin and validated by measurements recorded during the aircraft cruise phase. Ozone concentrations in the supply air-dominated area were approximately 50% higher than that in the passenger breathing zone, suggesting that human surfaces represent a significant ozone sink. The deposition velocity onto human bodies was 21.83 m/h, surpassing 3.97 m/h on other cabin interior surface areas. Our model provides a mechanistic tool to analyze ozone and byproduct concentration distributions, which would be useful for assessing passenger health risks and for developing strategies for healthier aircraft cabin environments.


Asunto(s)
Contaminación del Aire Interior , Contaminantes Ambientales , Ozono , Humanos , Ozono/análisis , Contaminación del Aire Interior/análisis , Aeronaves , Hidrodinámica
4.
Indoor Air ; 32(11): e13153, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437662

RESUMEN

We performed a cross-sectional survey of 2143 female students in a university in Tianjin, China regarding perceived air quality (PAQ) and sick building syndrome (SBS) symptoms in the student dormitory. The prevalence of general, mucosal, and skin symptoms was 22.1%, 21.9%, and 26.3%, respectively. The three most prevalent PAQ complaints were "dry air" (48.9% often), "stuffy odor" (18.2%), and "other unpleasant odors" (5.1%), and they were significant risk factors for 11-12 out of 12 SBS symptoms (adjusted odds ratios [AOR]: 1.6-5.8). Survey data of 1471 undergraduates, whose dorms were of uniform layout and furnishing, were used to further investigate the influences of occupancy level and occupant behaviors on PAQ and SBS symptoms. Frequent use of air freshener/perfume was a significant risk factor for "dry air," less frequent room cleaning and higher occupancy density were significant risk factors for "stuffy odor," and less natural ventilation was a significant risk factor for both "stuffy odor" and "pungent odor." These factors were also significantly associated with some SBS symptoms. In particular, the use of air freshener/perfume exhibited a significant dose-response pattern with "fatigue" (sometimes: AOR 1.3; often: AOR 2.0) and with "irritated, stuffy, or runny nose" (sometimes: AOR 1.6; often: AOR 2.2).


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Perfumes , Síndrome del Edificio Enfermo , Humanos , Femenino , Síndrome del Edificio Enfermo/epidemiología , Síndrome del Edificio Enfermo/etiología , Estudios Transversales , Contaminación del Aire Interior/efectos adversos , Estudiantes
5.
Indoor Air ; 32(11): e13170, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437665

RESUMEN

The burden of disease attributed to the indoor exposure to sulfur dioxide (SO2 ), nitrogen dioxide (NO2 ), ozone (O3 ), and carbon monoxide (CO) is not clear, and the quantitative concentration-response relationship is a prerequisite. This is a systematic review to summarize the quantitative concentration-response relationships by screening and analyzing the polled effects of population-based epidemiological studies. After collecting literature published between 1980 and 2019, a total of 19 health outcomes in 101 studies with 182 health risk estimates were recruited. By meta-analysis, the leave-one-out sensitivity analysis and Egger's test for publication bias, the robust and reliable effects were found for SO2 (per 10 µg/m3 ) with chronic obstructive pulmonary diseases (COPD) (pooled relative risks [RRs] 1.016, 95% CI: 1.012-1.021) and cardiovascular diseases (CVD) (RR 1.012, 95%CI: 007-1.018), respectively. NO2 (per 10 µg/m3 ) had the pooled RRs for childhood asthma, preterm birth, lung cancer, diabetes, and COPD by 1.134 (1.084-1.186), 1.079 (1.007-1.157), 1.055 (1.010-1.101), 1.019 (1.009-1.029), and 1.016 (1.012-1.120), respectively. CO (per 1 mg/m3 ) was significantly associated with Parkinson's disease (RR 1.574, 95% CI: 1.069-2.317) and CVD (RR 1.024, 95% CI: 1.011-1.038). No robust effects were observed for O3 . This study provided evidence and basis for further estimation of the health burden attributable to the four gaseous pollutants.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminación del Aire , Enfermedades Cardiovasculares , Ozono , Nacimiento Prematuro , Enfermedad Pulmonar Obstructiva Crónica , Recién Nacido , Femenino , Humanos , Niño , Dióxido de Nitrógeno , Monóxido de Carbono , Dióxido de Azufre , Contaminación del Aire/análisis , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Azufre
6.
Artículo en Inglés | MEDLINE | ID: mdl-36360961

RESUMEN

Phthalates are ubiquitous 'modern' chemical compounds with potential negative impacts on children's health. A nested case-control study was designed to investigate associations of phthalate exposure with children's asthma and allergic symptoms. We collected 243 first morning urine samples from 4-8-year-old children in Tianjin, China. Eight metabolites (i.e., mono-ethyl phthalate (MEP), mono-isobutyl phthalate (MiBP), mono-n-butyl phthalate (MnBP), mono-benzyl phthalate (MBzP) and mono-2-ethylhexyl phthalate (MEHP), mono-(2-ethyl-5-carboxylpentyl) phthalate (MECPP), mono-(2-ethyl-5-hydroxyhexyl) phthalate (MEHHP) and mono-(2-ethyl-5-oxohexyl) phthalate (MEOHP)) of five phthalates were analyzed using HPLC-MS. MiBP, MnBP and MECPP were the dominant phthalate metabolites in urine of children in Tianjin with median concentrations of 31.6 µg/L, 26.24 µg/L and 46.12 µg/L, respectively. We found significantly positive associations of diagnosed asthma with MnBP (adjusted odds ratios (AOR): 1.96; 95% confidence intervals (CIs): 1.07-3.61), MEHHP (AOR: 2.00; 95% CI: 1.08-3.71) and MEOHP (AOR: 2.09; 95% CI: 1.06-4.10). Our study indicates that phthalate exposure in childhood, especially to di-n-butyl phthalate (DnBP) and di(2-ethylhexyl) phthalate (DEHP), may be a risk factor for children's asthma.


Asunto(s)
Asma , Contaminantes Ambientales , Ácidos Ftálicos , Niño , Humanos , Preescolar , Contaminantes Ambientales/orina , Estudios de Casos y Controles , Ácidos Ftálicos/orina , Asma/inducido químicamente , Asma/epidemiología , Exposición a Riesgos Ambientales
7.
Indoor Air ; 32(10): e13141, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36305078

RESUMEN

Exposure to formaldehyde causes a variety of adverse health outcomes, while the distributions of indoor formaldehyde in different building types are still not clear in China. In this study, based on the systematic review of previously published data and Monte Carlo simulation, we assessed geographical and temporal distributions of indoor formaldehyde concentrations in residences, schools, and offices across China. A total of 397 studies covered 34 provincial-level regions since 1986 were collected. The results showed that indoor formaldehyde concentrations in residences, schools, and offices in nationwide were decreasing over years due to the publishment of indoor air quality standards since 2002. During 2011 to 2015, the median concentrations of indoor formaldehyde in newly renovated residences, schools, and offices were 153 µg/m3 , 163 µg/m3 , and 94 µg/m3 , with an exceeding rate of 82%, 46%, and 91% considering a standard threshold of 100 µg/m3 at that time, while the exceeding rate was less than 5% for buildings that were renovated beyond one year. Our findings release the temporal trends and geographic distributions of indoor formaldehyde concentrations in residences, schools, and offices in China in the past 30 years, and provide basic data for the comprehensive evaluation of disease burden attributable to indoor formaldehyde exposure.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Hipersensibilidad Respiratoria , Humanos , Contaminación del Aire Interior/análisis , Formaldehído/análisis , Vivienda , Instituciones Académicas , Hipersensibilidad Respiratoria/inducido químicamente , China , Contaminantes Atmosféricos/análisis
8.
Indoor Air ; 32(9): e13091, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36168233

RESUMEN

The last two decades have witnessed rapid urbanization and economic growth accompanied by severe indoor air pollution of volatile organic compounds (VOCs) in China. However, indoor VOC pollution across China has not been well characterized and documented. This study is a systematic review of field measurements of eight target VOCs (benzene, toluene, xylenes, acetaldehyde, p-dichlorobenzene, butadiene, trichloroethylene, and tetrachloroethylene) in residences, offices, and schools in China from 2000 to 2021. The results show that indoor pollution of benzene, toluene, and xylenes has been more serious in China than in other countries. Spatiotemporal distribution shows lower indoor VOC levels in east and south-east regions and a declining trend from 2000 to 2021. Moving into a dwelling more than 1 year after decoration and improving ventilation could significantly reduce exposure to indoor VOCs. Reducing benzene exposure is urgently needed because it is associated with greater health risks (4.5 × 10-4 for lifetime cancer risk and 8.3 for hazard quotient) than any other VOCs. The present study enriches the database of indoor VOC levels and provides scientific evidence for improving national indoor air quality standards as well as estimating the attributable disease burden caused by VOCs in China.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Tetracloroetileno , Tricloroetileno , Compuestos Orgánicos Volátiles , Acetaldehído , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Benceno/análisis , Butadienos , China , Monitoreo del Ambiente , Medición de Riesgo , Instituciones Académicas , Tolueno , Compuestos Orgánicos Volátiles/análisis , Xilenos/análisis
9.
Indoor Air ; 32(8): e13084, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-36040279

RESUMEN

House dust mites produce well-known allergens for asthma and allergy among children. To study house dust mite allergen exposure level in northeast China and characterize its association with indoor environmental factors and cleaning habits, we inspected 399 homes in Tianjin area and collected dust from mattresses. Dermatophagoides farinae (Der f) and Dermatophagoides pteronyssinus (Der p) were detected by the enzyme-linked immunosorbent assay (ELISA) method. The medians of total allergen concentrations for spring, summer, autumn, and winter were 524 ng/g, 351 ng/g, 1022 ng/g, and 1010 ng/g. High indoor air relative humidity (RH), low air change rate, indoor dampness, and frequent changing of quilt cover/bedsheet/pillow case were significantly associated with high house dust mite allergen concentration (relative risk [RR]: RH, 1.18-1.34; air change rate, 0.97-1.00; dampness, 2.92-3.83; changing quilt cover/bedsheet/pillow case, 0.66-0.75). The decrease in the absolute humidity gradient between indoors and outdoors that occurs with increased air change rate may explain why a high ventilation reduces house dust mite allergen concentration. The findings of this study show the importance of ventilation and cleaning for controlling house dust mite allergens. We found that the decrease in additional absolute humidity (e.g., humidity indoor -humidity outdoor ) with increased air change rate may be the main reason that a high ventilation rate reduces house dust mite allergen concentration. Ventilation and cleaning should be both considered for creating a healthy home environment.


Asunto(s)
Contaminación del Aire Interior , Ambiente en el Hogar , Contaminación del Aire Interior/análisis , Alérgenos/análisis , Animales , Antígenos Dermatofagoides , Niño , Polvo/análisis , Humanos , Estilo de Vida , Pyroglyphidae
10.
Environ Int ; 167: 107456, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35952466

RESUMEN

BACKGROUND: Although mounting evidence has associated air pollution and environmental temperature with children's health problems, it is unclear whether there is an interaction between these factors on childhood asthma. OBJECTIVES: To explore the effects of temperature-pollution interactions during pre- and post-natal periods on asthma among pre-schoolers. METHODS: A retrospective cohort study of 39,782 pre-schoolers was performed during 2010-2012, in seven cities in China. Exposure to three temperature indicators (TI) and three critical ambient air pollutants, including particulate matter with aerodynamic diameter ≤ 10 µm (PM10), sulfur dioxide (SO2) and nitrogen dioxide (NO2) as proxies of industrial and vehicular air pollution, was estimated by an inverse distance weighted (IDW) method. Two-level logistical regression analysis was used to examine the association between both pre- and post-natal exposure and childhood asthma in terms of odds ratio (OR) and 95 % confidence interval (CI). RESULTS: Asthma prevalence in pre-schoolers at age of 3-6 years (6.9 %) was significantly associated with traffic-related air pollutant (NO2) exposure, with ORs (95 % CI) of 1.17 (1.06, 1.28), 1.19 (1.05-1.34) and 1.16 (1.03-1.31) for an IQR increase in NO2 exposure during lifetime, pregnancy, and entire postnatal period respectively. Furthermore, childhood asthma was positively associated with exposure to increased temperature during lifetime, pregnancy, and entire postnatal period with ORs (95 % CI) = 1.89 (1.66, 2.16), 1.47 (1.34, 1.61), and 1.15 (1.11, 1.18) respectively, while was negatively associated with decreased temperatures. Childhood asthma was positively related with exposure to extreme heat days (EHD) during postnatal period particularly in first year of life respectively with ORs (95 % CI) = 1.23 (1.04, 1.46) and 1.26 (1.07, 1.47), but was not related with extreme cold days (ECD) exposure. A combination of high air pollutant levels and high temperatures significantly increased the risk of asthma during both pre- and post-natal periods. Strikingly, we found a significantly positive interaction of temperature and PM10 or SO2 on asthma risk among boys and younger children. CONCLUSIONS: Prenatal and postnatal exposure to ambient air pollution and high temperatures are independently and jointly associated with asthma risk in early childhood.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Asma , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Contaminación del Aire/efectos adversos , Contaminación del Aire/análisis , Asma/epidemiología , Asma/etiología , Niño , Preescolar , China/epidemiología , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Femenino , Humanos , Masculino , Dióxido de Nitrógeno/efectos adversos , Dióxido de Nitrógeno/análisis , Material Particulado/efectos adversos , Material Particulado/análisis , Embarazo , Estudios Retrospectivos , Temperatura
11.
Indoor Air ; 32(6): e13063, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35762240

RESUMEN

Common cold is usually considered to be associated with outdoor climate, but the evidence linking with indoor environmental factors is lacking. The role of indoor renovations during which critical timing window on childhood common cold remains unclear. Therefore, we investigated the effect of exposure to new furniture and/or redecoration during prenatal and postnatal periods on the occurrence and duration of common cold in preschool children. We conducted a retrospective cohort study of 39 782 children aged 3-6 years in seven cities of China. The occurrence and duration of common cold in children, and their lifetime exposures to indoor new furniture and redecoration (including pregnancy, the first year of life, and after one year old) were assessed using a questionnaire administered by the parents. Associations between high frequency (>5 colds) and long duration (≥2 weeks per cold) of common cold during past 12 months and exposure to indoor new furniture/redecoration were examined by logistic regression models in terms of odds ratio (OR) and 95% confidence interval (CI). We found that the prevalence of high frequency and long duration of common cold in preschool children in China were, respectively, 9.2% and 11.9%. Frequent common cold was significantly associated with exposure to indoor new furniture/redecoration during pregnancy, first year, and after 1 year old, respectively, with the ORs (95% CI) = 1.25 (1.12-1.39), 1.11 (1.00-1.25), and 1.09 (1.01-1.18). Furthermore, childhood long duration per cold was associated with exposure to indoor new furniture/redecoration during pregnancy with OR (95% CI) of 1.14 (1.03-1.25) but not with postnatal exposure. We identified that prenatal exposure to home renovation was more critical than postnatal exposure for an increased risk of high frequency and long duration of common cold. Sensitivity analysis showed that the association between prenatal exposure to indoor renovations and the risk of childhood common cold was consistent and robust, and the associations were modified by some personal and indoor environmental factors. Our findings indicated that prenatal and postnatal exposure to home renovation played an important role in the risk of childhood common cold, supporting the hypothesis of "fetal origin of childhood infection."


Asunto(s)
Contaminación del Aire Interior , Resfriado Común , Efectos Tardíos de la Exposición Prenatal , Contaminación del Aire Interior/análisis , Preescolar , China/epidemiología , Resfriado Común/epidemiología , Exposición a Riesgos Ambientales , Femenino , Humanos , Lactante , Embarazo , Estudios Retrospectivos , Factores de Riesgo
12.
Indoor Air ; 32(5): e13038, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35622720

RESUMEN

Exposure to volatile organic compounds (VOCs) indoors is thought to be associated with several adverse health effects. However, we still lack concentration-response (C-R) relationships between VOC levels in civil buildings and various health outcomes. For this paper, we conducted a systematic review and meta-analysis of observational studies to summarize related associations and C-R relationships. Four databases were searched to collect all relevant studies published between January 1980 and December 2017. A total of 39 studies were identified in the systematic review, and 32 of these were included in the meta-analysis. We found that the pooled relative risk (RR) for leukemia was 1.03 (95% CI: 1.01-1.05) per 1 µg/m3 increase of benzene and 1.25 (95%CI: 1.14-1.37) per 0.1 µg/m3 increase of butadiene. The pooled RRs for asthma were 1.08 (95% CI: 1.02-1.14), 1.02 (95% CI: 1.00-1.04), and 1.04 (95% CI: 1.02-1.06) per 1 µg/m3 increase of benzene, toluene, and p-dichlorobenzene, respectively. The pooled RR for low birth weight was 1.12 (95% CI: 1.05-1.19) per 1 µg/m3 increase of benzene. Our findings provide robust evidence for associations between benzene and leukemia, asthma, and low birth weight, as well as for health effects of some other VOCs.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Asma , Leucemia , Compuestos Orgánicos Volátiles , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Benceno/análisis , Humanos , Leucemia/epidemiología , Leucemia/etiología , Estudios Observacionales como Asunto , Compuestos Orgánicos Volátiles/análisis
13.
Environ Int ; 165: 107315, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35635966

RESUMEN

BACKGROUND: Increasing prevalence of childhood allergic rhinitis(AR) needs a deeper understanding on the potential adverse effects of early life exposure to air pollution. OBJECTIVES: The main aim was to evaluate the effects of maternal exposure to PM2.5 and chemical constituents during pregnancy on preschool children's AR, and further to explore the modification effects of regions and exclusive breastfeeding. METHODS: A multi-center population-based study was performed in 6 cities from 3 regions of China in 2011-2012. Maternal exposure to ambient PM2.5 and main chemical constituents(BC, OM, SO42-, NO3-, NH4+) during pregnancy was assessed and a longitudinal prospective analysis was applied on preschool children's AR. The modification effects of regions and exclusive breastfeeding were investigated. RESULTS: A total of 8.8% and 9.8% of children reported doctor-diagnosed allergic rhinitis(DDAR) and current hay fever, respectively, and 48.6% had less than 6 months of exclusive breastfeeding. The means of PM2.5 during pregnancy were 52.7 µg/m3, 70.3 µg/m3 and 76.4 µg/m3 in the east, north and central south of China, respectively. Multilevel log-binomial model regression showed that each interquartile range(IQR) increase of PM2.5 during pregnancy was associated with an average increase in prevalence ratio (PR) of DDAR by 1.43(95% confidence interval(CI): 1.11, 1.84) and current hay fever by 1.79(95% CI: 1.26, 2.55), respectively. Among chemical constituents, black carbon (BC) had the strongest associations. Across 3 regions, the eastern cities had the highest associations, followed by those in the central south and the north. For those equal to or longer than 6 months of exclusive breastfeeding, the associations were significantly reduced. CONCLUSIONS: Children in east of China had the highest risks of developing AR per unit increase of maternal exposure to PM2.5 during pregnancy, especially BC constituent. Remarkable decline was found in association with an increase in breastfeeding for ≥6 months, in particular in east of China.


Asunto(s)
Contaminantes Atmosféricos , Rinitis Alérgica Estacional , Rinitis Alérgica , Contaminantes Atmosféricos/análisis , Lactancia Materna , Preescolar , Femenino , Humanos , Exposición Materna/efectos adversos , Material Particulado/análisis , Embarazo , Rinitis Alérgica/epidemiología , Rinitis Alérgica/etiología , Rinitis Alérgica Estacional/inducido químicamente , Hollín/análisis
14.
Chemosphere ; 302: 134786, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35508265

RESUMEN

Prevalences of allergies and asthma have increased through the past few decades around the world, especially in countries and regions that have adopted modern lifestyles. Epidemiological studies outside of China have found a relationship between phthalates concentrations in indoor dust and symptoms of respiratory, skin and nose allergies. The aim of our study is to investigate the association between children's asthma and allergic symptoms and concentrations of different phthalates in settled dust samples collected from children's homes in metropolitan Tianjin (Tianjin and Cangzhou), China. We selected 126 cases with current allergic symptoms and 254 controls without allergic symptoms from the cohort of 7865 children. We collected dust samples from children's bedroom and analyzed them for their content of diethyl phthalate (DEP), diisobutyl phthalate (DiBP), di-n-butyl phthalate (DnBP), butylbenzyl phthalate (BBzP), di-2-ethylhexyl phthalate (DEHP) and diisononyl phthalate (DiNP). We found a higher concentration of DEP in rhinitis children's homes (0.33 vs. 0.27 µg/g dust) and a higher concentration of DiBP in asthma children's homes (29.04 vs. 15.66 µg/g dust). The concentration of DiBP was significantly associated with diagnosed asthma (adjusted odds ratio (AOR): 1.30; 95% confidence interval (CI): 1.07, 1.57). A dose-response relationship was found between concentrations of DiBP in dust and asthma. This study shows that some phthalates are associated with allergic and asthma symptoms in children.


Asunto(s)
Asma , Hipersensibilidad , Ácidos Ftálicos , Asma/inducido químicamente , Asma/epidemiología , Niño , Polvo , Exposición a Riesgos Ambientales , Humanos , Hipersensibilidad/epidemiología , Ácidos Ftálicos/análisis , Prevalencia
15.
Indoor Air ; 32(4): e13030, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35481931

RESUMEN

China's profoundly rapid modernization in the past two decades has resulted in dramatic changes in indoor environmental exposures. Among these changes, exposure to phthalates has attracted increasing attention. We aimed to characterize indoor phthalate exposure and to estimate the disease burden attributable to indoor phthalate pollution from 2000 to 2017 in China. We integrated the national exposure level of indoor phthalates from literature through systematic review and Monte Carlo simulation. Dose-response relationships between phthalate exposure and health outcomes were obtained by systematic review and meta-analysis. Based on existing models for assessing probabilities of causation and a comprehensive review of available data, we calculated the disability-adjusted life years (DALYs) among the general Chinese population resulting from exposure to indoor phthalate pollution. We found that DnBP, DiBP, and DEHP were the most abundant phthalates in indoor environments of residences, offices, and schools with medians of national dust phase concentration from 74.5 µg/g to 96.3 µg/g, 39.6 µg/g to 162.5 µg/g, 634.2 µg/g to 1,394.7 µg/g, respectively. The national equivalent exposure for children to phthalates in settled dust was higher than that of adults except for DiBP and DnOP. Dose-response relationships associated with DEP, DiBP, DnBP, BBzP, and DEHP exposures were established. Between 2000 and 2017, indoor phthalate exposure in China has led to 3.32 million DALYs per year, accounting for 0.90% of total DALYs across China. The annual DALY associated with indoor phthalate pollution in China was over 2000 people per million, which is about 2~3 times of the DALY loss due to secondhand smoke (SHS) in six European countries or the sum of the DALY loss caused by indoor radon and formaldehyde in American homes. Our study indicates a considerable socioeconomic impact of indoor phthalate exposure for a modernizing human society. This suggest the need for relevant national standard and actions to reduce indoor phthalate exposure.


Asunto(s)
Contaminación del Aire Interior , Dietilhexil Ftalato , Adulto , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Niño , China/epidemiología , Costo de Enfermedad , Dietilhexil Ftalato/análisis , Polvo/análisis , Humanos , Ácidos Ftálicos , Estados Unidos
16.
Environ Int ; 158: 106999, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34991259

RESUMEN

The identification of key VOCs during flights is important in creating a satisfactory aircraft cabin environment. Two VOC databases for the building indoor environment (from 251 occupied residences) and the aircraft cabin environment (from 56 commercial flights) were compared, to determine the common compounds (detection rate (DR) > 70%) in the two environments and the characteristic VOCs (only those with high DR during flights) in aircraft cabins. Possible VOC emission sources in flights were also discussed. As TVOC is usually viewed as a general indicator of air quality, the prediction of TVOC concentration was carried out using BP neural network algorithm, and the average error between the predicted and measured values was 55.35 µg/m3 (R2 = 0.80). Meanwhile, the VOCs' inhalation cancer/non-cancer risks to crew members and passengers were calculated on the basis of detection rates, exposure concentrations, and health risk assessments. Six compounds (i.e., formaldehyde, benzene, tetrachloroethylene, trichloromethane, 1,2-dichloroethane, and naphthalene) were proposed as the key VOCs in the existing aircraft cabin environment, presenting a risk to crew members that is higher than the US EPA proposed acceptable level (evaluated mean value > 1E-06). The estimated lifetime excess cancer/non-cancer risks for passengers were all below the assessment criteria. Based on a summary of various VOC limits in five built environments, hierarchical design of VOC concentration limits is recommended for the aircraft environment.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminación del Aire , Compuestos Orgánicos Volátiles , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Aeronaves , Formaldehído/análisis , Compuestos Orgánicos Volátiles/análisis
17.
Artículo en Inglés | MEDLINE | ID: mdl-36613006

RESUMEN

People spend a considerable portion of their lives indoors; thus, the quality of the indoor environment is crucial. Semi-volatile organic compounds (SVOCs) are among the primary indoor pollutants responsible for various health risks. This paper systematically reviews the impact of SVOC exposure on human health in Chinese built environments. Based on a set of criteria, we judged 12 publications as providing sufficient information on both SVOC exposure and health effects to inform the relationship. Out of six studies on polycyclic aromatic hydrocarbons (PAHs), three observed a positive association between PAH exposure and lung cancer. Out of six studies of phthalate exposure, two studies reported a significant positive association between DEP and DiBP and asthma, between DEP and DEHP and dry cough among children, and between DBP and rhinitis among younger adults. The results of this review suggest that there might be a link between phthalate exposure and asthma and allergies, as well as a link between PAH exposure and lung cancer. However, due to the limited number of studies conducted, more evidence is necessary to definitively guide the establishment of standards for SVOC control in China.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Asma , Neoplasias Pulmonares , Ácidos Ftálicos , Hidrocarburos Policíclicos Aromáticos , Compuestos Orgánicos Volátiles , Adulto , Niño , Humanos , Contaminantes Atmosféricos/toxicidad , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Asma/inducido químicamente , Asma/epidemiología , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Ácidos Ftálicos/análisis , Hidrocarburos Policíclicos Aromáticos/toxicidad , Hidrocarburos Policíclicos Aromáticos/análisis , Compuestos Orgánicos Volátiles/toxicidad , Compuestos Orgánicos Volátiles/análisis , China
18.
Indoor Air ; 32(1): e12920, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34432341

RESUMEN

After decades of development, the indoor environment in China has changed. A systematic review was conducted from peer-reviewed scientific papers with field test data of indoor radon in China from 2000 to 2020 for three types of buildings. The mean concentrations of indoor radon for dwellings, school buildings, and office buildings are 54.6, 56.1, and 54.9 Bq/m3 . The indoor radon concentration was related to seasons, climate regions, ventilation, decoration, and other factors such as soil and outdoor air. Colder seasons, especially in severe colder areas of China, newer decorated buildings, closed windows, and doors were all associated with higher indoor radon concentrations. Variables like climate region and ventilation showed statistical significance in the correlation analysis. Regarding the increasing trend of indoor radon concentration in China during the last two decades, further study of indoor radon is necessary especially for school buildings and office buildings, and will help access its environmental burden of disease in China more accurately.


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , Monitoreo de Radiación , Radón , Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , China , Vivienda , Radón/análisis , Instituciones Académicas
19.
Indoor Air ; 32(1): e12918, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34337784

RESUMEN

A questionnaire survey on dermal symptoms and home environment was performed in eight Chinese cities (40 279 participants). Data on city level temperature, precipitation, PM10 , NO2, and gross domestic product (GDP) per capita were collected. In total, 2.2% had eczema, 2.4% facial erythema (FE) and 2.6% seborrheic dermatitis symptoms (SD). Higher temperature was associated with eczema (OR = 1.09). Higher GDP per capita was related to less SD. Higher PM10 was related to SD. Suburban living was protective for eczema (OR = 0.77) (vs. urban). Living in old buildings (built before 1991) was related to eczema (OR = 1.42). Living near heavily trafficked roads was related to FE (OR = 1.33) and SD (OR = 1.35). Having new furniture was related to all symptoms (OR = 1.26-1.47). Burning mosquito coils (OR = 1.37-1.57) and incense (OR = 1.33-1.37) were associated with eczema, FE, or SD. Presence of cockroaches and rats/mice was associated with FE or SD (OR = 1.31-1.40). Using air conditioner, daily cleaning and frequently exposing bedding to sunshine were protective (OR = 0.60-0.83). In conclusion, higher temperature, higher PM10 , urban living, living near heavily trafficked roads, old buildings, new furniture, burning mosquito coils and incense, and presence of cockroaches/rats/mice increased the risk of eczema, FE, or SD. Higher GDP, air conditioner, daily cleaning, and exposing bedding to sunshine were protective.


Asunto(s)
Contaminación del Aire , Dermatitis Seborreica , Eccema , Eritema , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Contaminación del Aire/análisis , Contaminación del Aire/estadística & datos numéricos , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Animales , China/epidemiología , Dermatitis Seborreica/epidemiología , Eccema/epidemiología , Eritema/epidemiología , Eritema/etiología , Ambiente en el Hogar , Humanos , Ratones , Material Particulado/análisis , Material Particulado/toxicidad , Ratas , Factores de Riesgo , Adulto Joven
20.
MethodsX ; 8: 101187, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34434718

RESUMEN

This paper provides a method for evaluating indoor phthalate exposure levels in collected dust, including dust collection, chemical analysis and quality control. Indoor dusts were collected with a self-made equipment and pretreated by the Soxhlet extractor method. Six phthalates, i.e., diethyl phthalate (DEP), di-n-butyl phthalate (DnBP), di-isobutyl phthalate (DiBP), benzyl butyl phthalate (BBzP), di (2-ethylhexyl) phthalate (DEHP) and di-isononyl phthalate (DiNP) in the dust were analyzed by gas chromatography mass spectrometry (GC-MS). •Measures were taken to avoid background contamination of phthalates during sampling and chemical analysis to accurately evaluate the indoor phthalates exposure levels.•Filter sock and self-made mouthpiece mounted on vacuum cleaner were made of nylon and aluminum respectively.•Dust from surface of plastic products was avoided. The pretreatment of vessels and analysis of blank samples were conducted to reduce "noise" from background contamination.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...